MetalWorks RH200 System Performance Data


Product Type
Ceilings Walls Suspension Systems Trims & Transitions Building Perimeter Systems Drywall Grid Systems

Chat Live

Fire

Metal ceiling panels are inherently incombustible, however the paint surface and acoustical fleece backing can contribute to fire if not properly formulated. RH200 Plank and Curved panels have been tested according to ASTM E84 and are certified Class A by Factory Mutual:

  • Flame Spread Index of 25 or less
  • Smoke Developed Index 50 or less

Acoustics

Acoustical correction is provided by the factory application of a black acoustical fleece. Additional correction can be provided by the addition of a fiberglass pad behind the fleece.

  • NRC rating, perforated with fleece: 0.65 (12% open) to 0.70 (40% open)
  • NRC rating, perforated with fleece and fiberglass pad: 0.90 (22% open)

Light Reflectance

Light reflectance of RH200 Plank and Curved Systems is dependent on the selection of color and perforation. The results below were obtained using a photo-spectrometer with a D65 10 degree setting; perforated panels were backed with black acoustical fleece.

Perforation Open Area Global White Silver Grey Gun Metal Grey

Unperforated

0%

89.45%

43.10%

22.24%

Rd 1511

11%

59.65%

37.13%

22.31%

Rd 324

20%

62.31%

38.24%

23.17%

Air Flow

RH200 Plank and Curved Systems are not normally considered for use as air supply or return elements. However, pressure drop and flow rate data is available from Armstrong on a variety of perforation types.

Exterior Applications

The RH200 Plank and Curved Systems are designed essentially as an interior systems. However, under certain circumstances, the systems can be installed in exterior soffit situations. Modifications to meet exterior requirements will typically include:

  • exterior coating finish specifications
  • restricted panel sizes to meet specified wind loads
  • additional hold down clips and increased frequency of support elements

Call 1 877 ARMSTRONG, selection options 1-1-4, for full data and test results on the performance topics listed above.