Clean Room Systems


Product Type
  • You Have Selected:Suspension SystemsChange Product Type
  • Ceilings
  • Walls
  • Trims and Transitions
  • Building Perimeter Systems
  • Drywall Grid Systems
Product Family
Line
  • 1-1/2" Co-Extruded Clean Room (14)
  • 15/16" Co-Extruded Clean Room (18)
  • DC FlexZone Silhouette
  • DC FlexZone Suprafine
  • Exposed Tee System Accessories
  • Interlude XL HRC
  • MetalWorks Linear Grid System
  • Prelude Concealed Tee
  • Prelude ML 15/16" Exposed Tee
  • Prelude Plus XL Aluminum 15/16" Exposed Tee
  • Prelude Plus XL Fire Guard 15/16" Exposed Tee
  • Prelude Plus XL Stainless Steel 15/16" Exposed Tee
  • Prelude XL 15/16" Exposed Tee
  • Prelude XL 15/16" for Exterior Applications
  • Prelude XL 360 Painted
  • Prelude XL Fire Guard 15/16" Exposed Tee
  • Prelude XL HRC
  • Silhouette XL 9/16" Bolt Slot - 1/4" Reveal
  • Silhouette XL 9/16" Bolt Slot - 1/8" Reveal
  • SingleSpan
  • Sonata 9/16" Dimensional Tee
  • Suprafine ML 9/16" Exposed Tee
  • Suprafine XL 9/16" Exposed Tee
  • Suprafine XL Fire Guard 9/16" Exposed Tee
  • Suprafine XL HRC
  • Trimlok 9/16" Screw-Slot
Space / Use Area
  • Atrium, Lobby / Reception Areas
  • Corridors
  • Exterior Soffits
  • Offices / Conference Rooms - Open Plan
  • Private Patient Rooms
Performance
System Type
  • Bolt-Slot
  • Concealed Tee
  • Dimensional Tee
  • Drywall/Stucco/Plaster
  • Exposed Tee (10)
  • Screw-Slot
Face Profile
Chat Live
 Clean Room Systems

Description

Clean Room grid systems offer a 15/16" and wider, 1-1/2" face to facilitate the use of clean room panels.

Performance

Performance Features

Color

Seismic Category

32 Products Compare up to 4 Products: Compare

15/16" Co-Extruded Clean Room

15/16" Co-Extruded Clean Room
All steel 15/16" face suspension system designed for maximum corrosion resistance. Suitable for clean rooms, food processing, data centers. Features factory applied gaskets for positive seal between panel and grid. Suitable for applications up to Class 5 performance per ISO Standard 14644 without the use of hold down clips.
DOWNLOAD DATA PAGE

Learn More about 15/16" Co-Extruded Clean Room


Main Beam 

Item # Description Length Face/Width Height Hangar Spacing
4'/5'
EA7900
Co-Extruded Aluminum Clean Room12ft ID Main Beam 1 144 IN 15/16 IN 1-11/16 IN 14.0 PLF
ES7901
12ft Co-Extruded Steel Clean Room HD Main Beam, 15 144 IN 15/16 IN 1-11/16 IN 16.00 PLF

Cross Tee 

Item # Description Length Face/Width Height Hangar Spacing
4'/5'
EA7920
Co-Extruded Aluminum Clean Room 2ft Cross Tee 15/1 24 IN 15/16 IN 1-11/16 IN
EA7940
Co-Extruded Aluminum Clean Room 4ft Cross Tee 15/1 48 IN 15/16 IN 1-11/16 IN 12.25 PLF
ES7920
2ft Co-Extruded Steel Clean Room Cross Tee 15/16" 24 IN 15/16 IN 1-11/16 IN
ES7940
4ft Co-Extruded Steel Clean Room Cross Tee 15/16" 48 IN 15/16 IN 1-11/16 IN

Molding 

Item # Description Length Face/Width Height Hangar Spacing
4'/5'
EA7801
Co-Extruded Aluminum Clean Room 12ft Angle Molding 144 IN 15/16 IN 15/16 IN
ES7801
12ft Steel Clean Room Molding 144 IN 15/16 IN 15/16 IN

Accessory 

Item # Description Length Face/Width Height Hangar Spacing
4'/5'
CHDC
Hold Down Clip      
STAC
Accessory- single tee adapter clip      
XTAC
Cross Tee Adapter Clip      
7901
Molding Transition 3/8" Reveal 9/16" 120 IN 2-5/16 IN 1-1/4 IN
7902
Molding Transition 3/8" Reveal 15/16" 120 IN 2-11/16 IN 1-1/4 IN
7903
Molding Transition 15/16" 120 IN 15/16 IN 1-1/2 IN
7904
Transition Molding for Drywall 120 IN 1-1/4 IN  
7905
Transition Molding for Drywall 120 IN 1-1/4 IN  
7906
Transition Molding for Drywall 120 IN 3/8 IN  
7907
Transition Molding for Drywall 120 IN 1-1/4 IN  
More ▼
Less ▲

1-1/2" Co-Extruded Clean Room

1-1/2" Co-Extruded Clean Room
All aluminum 15/16" & 1-1/2" face suspension system designed for maximum corrosion resistance and non-magnetic environments. Suitable for clean rooms, food processing, data centers, nonmagnetic areas such as MRI suites.Features factory applied gaskets for positive seal between panel and grid. Suitable for applications up to Class 5 performance per ISO Standard 14644 without the use of hold down clips.
DOWNLOAD DATA PAGE

Learn More about 1-1/2" Co-Extruded Clean Room


Main Beam 

Item # Description Length Face/Width Height Hangar Spacing
4'/5'
EA7903
Co-Extruded AluminumClean Room 12ft ID Main Beam 1 144 IN 1-1/2 IN 2 IN 14.0 PLF
8.4 PLF

Cross Tee 

Item # Description Length Face/Width Height Hangar Spacing
4'/5'
EA7927
Co-Extruded Aluminum Clean Room 2ft Cross Tee 1-1/ 24 IN 1-1/2 IN 2 IN
EA7947
Co-Extruded Aluminum Clean Room 4ft Cross Tee 1-1/ 48 IN 1-1/2 IN 2 IN 18.30 PLF

Molding 

Item # Description Length Face/Width Height Hangar Spacing
4'/5'
EA7801
Co-Extruded Aluminum Clean Room 12ft Angle Molding 144 IN 15/16 IN 15/16 IN

Accessory 

Item # Description Length Face/Width Height Hangar Spacing
4'/5'
CHDC
Hold Down Clip      
STAC
Accessory- single tee adapter clip      
XTAC
Cross Tee Adapter Clip      
7901
Molding Transition 3/8" Reveal 9/16" 120 IN 2-5/16 IN 1-1/4 IN
7902
Molding Transition 3/8" Reveal 15/16" 120 IN 2-11/16 IN 1-1/4 IN
7903
Molding Transition 15/16" 120 IN 15/16 IN 1-1/2 IN
7904
Transition Molding for Drywall 120 IN 1-1/4 IN  
7905
Transition Molding for Drywall 120 IN 1-1/4 IN  
7906
Transition Molding for Drywall 120 IN 3/8 IN  
7907
Transition Molding for Drywall 120 IN 1-1/4 IN  