Search Results

The following 22 item(s) match your selection criteria(s). Click on Ceiling name or Item Number to learn more.
     
Market Segment Office "A" Grade Open Plan

Ultima

Durability 
Relative Installed Cost
 
Item # Edge Profile
Grid Face
Design Name
Dimensions Pattern NRC CAC Fire Resist Sag Resist Light Reflect
1911M Beveled Tegular
24 MM
600x600x19 MM
0.70
35 Standard Fire Resist Performance
RH99

0.90
1912M Beveled Tegular
15 MM
600x600x19 MM
0.70
35 Standard Fire Resist Performance
RH99

0.90
1913M Square Lay-In
24 MM
1200x600x19 MM
0.70
35 Standard Fire Resist Performance
RH99

0.90
1914M Beveled Tegular
24 MM
1200x600x19 MM
0.70
35 Standard Fire Resist Performance
RH99

0.90
1915M Beveled Tegular
15 MM
1200x600x19 MM
0.70
35 Standard Fire Resist Performance
RH99

0.90
1920M Vector
24 MM
600x600x19 MM
0.70
33 Standard Fire Resist Performance
RH99

0.90
G19300 Square Lay-In
24 MM
Prima RH95
1200x400x17 MM
0.70
35 Standard Fire Resist Performance
RH99

0.90
G19301 Beveled Tegular
24 MM
Prima RH95
1200x400x17 MM
0.70
35 Standard Fire Resist Performance
RH99

0.90
G19302 K2C2
N/A MM
Prima RH95
1200x400x17 MM
0.70
40 Standard Fire Resist Performance
RH99

0.90
G19303 Shiplap
N/A MM
Prima RH95
1200x400x17 MM
0.70
40 Standard Fire Resist Performance
RH99

0.90
G19304 Square Lay-In
24 MM
Prima RH95
1350x450x17 MM
0.70
35 Standard Fire Resist Performance
RH99

0.90
G19305 Beveled Tegular
24 MM
Prima RH95
1350x450x17 MM
0.70
35 Standard Fire Resist Performance
RH99

0.90
G19306 K2C2
N/A MM
Prima RH95
1350x450x17 MM
0.70
40 Standard Fire Resist Performance
RH99

0.90
G19307 Shiplap
N/A MM
Prima RH95
1350x450x17 MM
0.70
40 Standard Fire Resist Performance
RH99

0.90

Fine Fissured High NRC/High CAC

Durability 
Relative Installed Cost
 
Item # Edge Profile
Grid Face
Design Name
Dimensions Pattern NRC CAC Fire Resist Sag Resist Light Reflect
1714M Square Lay-In
24 MM
High NRC/High CAC
1200x600x19 MM
0.70
40
Fire Guard

RH99

0.85

Optima Open Plan

Durability 
Relative Installed Cost
 
Item # Edge Profile
Grid Face
Design Name
Dimensions Pattern NRC CAC Fire Resist Sag Resist Light Reflect
2327M Square Lay-In
24 MM
600x600x15 MM
0.90
N/A Standard Fire Resist Performance
RH99

0.90
2328M Square Lay-In
24 MM
1200x600x15 MM
0.90
N/A Standard Fire Resist Performance
RH99

0.90
2329M Square Tegular
24 MM
600x600x15 MM
0.90
N/A Standard Fire Resist Performance
RH99

0.90
2331M Square Tegular
15 MM
600x600x15 MM
0.90
N/A Standard Fire Resist Performance
RH99

0.90
2332M Square Tegular
15 MM
1200x600x15 MM
0.90
N/A Standard Fire Resist Performance
RH99

0.90
3900M Vector
24 MM
600x600x22 MM
0.95
N/A Standard Fire Resist Performance
RH99

0.89
 
Result Pages: < Previous  1   2  Next >   Show All